Amount of
Space Unit Heats
up to 3500 Square feet |
 |
 |
Commonly
Used Fuels
Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel
oil, and diesel fuel |
 |
 |
Fuel Meter
Pump
Precision metering over a wide range of fuels |
 |
 |
UL Certification
UL listed system |
 |
 |
Fuel Flow
Rate
1.0 gallons/3.78 liters per hour |
 |
 |
BTU Input
142,000 BTU/41.6 kW per hour |
 |
 |
Warm Air
Temp. Rise
100-120 F/37.8-48.9 C |
 |
 |
Air Flow
1000 cfm/28 cu. m/min |
 |
 |
Warm Air
Outlet Dimensions
12"W x 12"H /31cm W x 31cm H
Ductible dual outlets
Air outlet can be on both sides |
 |
 |
Primary Heat
Exchanger
18 gauge high temperature and corrosion resistant stainless
steel, UL-rated at 1500 F/816 C |
 |
 |
System Dimensions
Cabinet -
18"H x 18"W x 92"L / 46cm H x 46cm W
x 234cm L
With Tank -
37.5"H x 32"W x 60"L (69"L w/pump)
95cm H x 82cm W x 153cm L (176cm L w/pump) |
 |
 |
Hour Meter
Analog (Clocks only actual burn time, not blower) |
 |
 |
Exhaust Flue
Diameter
8" / 20.32cm diameter |
 |
 |
Fuel Tank
Single wall 250 gal./946.35 liter workbench. Double
wall workbench available |
 |
 |
Electrical
Req.
115 VAC 60Hz, 25 amps dedicated curcuit |
 |
 |
Shipping
Weight
System with tank - 730lbs. / 332kg
System without tank - 375lbs. / 171kg |
 |
 |
Standard
Features
Integrated Air Compressor Barometric Damper, Draft Gauge,
Squirrel Cage Blower |
 |
 |
Optional
Features
Various Size Fuel Tanks, Dual Warm Air Outlet Louvers |
| |
|
|
 |
 |
Amount of
Space Unit Heats
up to 5000 Square feet |
 |
 |
Commonly
Used Fuels
Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel
oil, and diesel fuel |
 |
 |
Fuel Meter
Pump
Precision metering over a wide range of fuels |
 |
 |
UL Certification
UL listed system |
 |
 |
Fuel Flow
Rate
1.4 gallons/5.3 liters per hour |
 |
 |
BTU Input
200,000 BTU/58.3 kW per hour |
 |
 |
Warm Air
Temp. Rise
100-120 F/37.8-48.9 C |
 |
 |
Air Flow
1500 cfm/42 cu. m/min |
 |
 |
Warm Air
Outlet Dimensions
15"W x 15"H /38cm W x 38cm H
Ductible dual outlets
Air outlet can be on both sides |
 |
 |
Primary Heat
Exchanger
18 gauge high temperature and corrosion resistant stainless
steel, UL-rated at 2000 F/1093 C |
 |
 |
System Dimensions
Cabinet -
18"H x 18"W x 105"L / 46cm H x 46cm W
x 267cm L
With Tank -
37.5"H x 32"W x 60"L (69"L w/pump)
95cm H x 82cm W x 153cm L (176cm L w/pump) |
 |
 |
Hour Meter
Analog (Clocks only actual burn time, not blower) |
 |
 |
Exhaust Flue
Diameter
8" / 20.32cm diameter |
 |
 |
Fuel Tank
Single wall 250 gal./946.35 liter workbench. Double
wall workbench available |
 |
 |
Electrical
Req.
115 VAC 60Hz, 25 amps dedicated curcuit |
 |
 |
Shipping
Weight
System with tank - 750lbs. / 341kg
System without tank - 395lbs. / 180kg |
 |
 |
Standard
Features
Integrated Air Compressor Barometric Damper, Draft Gauge,
Squirrel Cage Blower |
 |
 |
Optional
Features
Various Size Fuel Tanks, Dual Warm Air Outlet Louvers |
| |
|
|
 |
 |
Amount of
Space Unit Heats
up to 8500 Square feet |
 |
 |
Commonly
Used Fuels
Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel
oil, and diesel fuel |
 |
 |
Fuel Meter
Pump
Precision metering over a wide range of fuels |
 |
 |
UL Certification
UL listed system |
 |
 |
Fuel Flow
Rate
2.25 gallons/8.5 liters per hour |
 |
 |
BTU Input
340,000 BTU/99.6 kW per hour |
 |
 |
Warm Air
Temp. Rise
100-120 F/37.8-48.9 C |
 |
 |
Air Flow
2800 cfm/79 cu. m/min |
 |
 |
Warm Air
Outlet Dimensions
19"W x 25"H /48cm W x 64cm H
Ductible dual outlets
Air outlet can be on both sides |
 |
 |
Primary Heat
Exchanger
18 gauge high temperature and corrosion resistant stainless
steel, UL-rated at 2000 F/1093 C |
 |
 |
System Dimensions
Cabinet -
28"H x 22"W x 99"L / 71cm H x 56cm W
x 252cm L
With Tank -
37.5"H x 32"W x 60"L (69"L w/pump)
95cm H x 82cm W x 153cm L (176cm L w/pump) |
 |
 |
Hour Meter
Analog (Clocks only actual burn time, not blower) |
 |
 |
Exhaust Flue
Diameter
8" / 20.32cm diameter |
 |
 |
Fuel Tank
Single wall 250 gal./946.35 liter workbench. Double
wall workbench available |
 |
 |
Electrical
Req.
115 VAC 60Hz, 25 amps dedicated curcuit |
 |
 |
Shipping
Weight
System with tank - 895lbs. / 406kg
System without tank - 545lbs. / 248kg |
 |
 |
Standard
Features
Integrated Air Compressor Barometric Damper, Draft Gauge,
Squirrel Cage Blower |
 |
 |
Optional
Features
Various Size Fuel Tanks, Dual Warm Air Outlet Louvers |
| |
|